Information: Teflon diaphragm electrical contacts
One.Diaphragm pressure gauge can be adapted to measure corrosive, easy to crystallize, easy to solidification, a solid floating animals and to avoid media pressure
Free media directly into the type of measuring gauge and prevent sediment build-up, easy to clean the occasion. The measured (controlled) pressure system automatically
Control and signaling (alarm). The diaphragm pressure gauge is located on the lower two switching contacts device (can choose three or four contacts Contact-type, according to the different control requirements can be different wiring) when the pressure reaches the set-off control signal or
Circuit for the operating system with automatic control or sender.
II. Manufacturing Specifications:
1 mirror material: glass or PC.
2 Housing: 304 stainless steel shell or HCPP, electrophoresis iron, chrome, fluorine rubber, high chemical resistance, PP stability, good deformation temperature 130 ℃.
3 Fill fluid: glycerol (99.5%).
4 within the machine Material: copper alloy.
5 connector size and material: PP, erect or buried within the standard tooth 1 / 2 "PT/1/2" NPT.
6 measuring devices and materials: brass pipe Baden, fluorine rubber, VITON <25kg/cm2 (bar) or a Teflon membrane, C-type tube.
7 panel material: aluminum, white with black font.
8 pointer Material: aluminum, black.
9 Diaphragm materials: fluorocarbon rubber or Teflon material.
三. 特性表 Three. Characteristic table
Serial Number |
TEL-65-6KG-A |
Pressure range |
0 ~ 0.5 KG, 1KG, 2KG, 3KG, 4KG, 5KG, 6KG, 7KG, 10KG, 15KG, 25KG, vacuum-0.1MPA ~ 0 |
Standard size |
63mm, 75mm, 100mm |
Accuracy |
± 1.5% |
Temperature range |
Max operating temperature 60 ℃ (in consideration of transmission characteristics), the ambient temperature of about -20 ℃ ~ 60 ℃ | |